{"id":4660,"date":"2026-09-10T02:00:00","date_gmt":"2026-09-10T02:00:00","guid":{"rendered":"https:\/\/www.26yc.com\/?p=4660"},"modified":"2026-10-08T23:36:10","modified_gmt":"2026-10-09T06:36:10","slug":"reset-air-standard","status":"publish","type":"post","link":"https:\/\/www.26yc.com\/de\/reset-air-standard\/","title":{"rendered":"RESET Air Standard"},"content":{"rendered":"<p><strong>RESET Air<\/strong> is the world&rsquo;s first sensor-based, performance-driven indoor-air-quality certification. Its Commercial Interiors <strong>v2.0<\/strong> standard is about continuous monitoring and transparent reporting, not a one-time design check. This article summarizes the monitored parameters and the targets a space must hold.<\/p>\n<h2>What Gets Monitored<\/h2>\n<p>RESET requires continuous monitors covering at least 80% of occupants across all regularly occupied space types, tracking PM2.5, TVOC, CO<sub>2<\/sub>, and CO. Temperature and relative humidity are monitored (no set limit) because they affect the particle and VOC sensors.<\/p>\n<h2>Performance Targets<\/h2>\n<table>\n<tr>\n<th>Parameter<\/th>\n<th>Acceptable<\/th>\n<th>High Performance<\/th>\n<\/tr>\n<tr>\n<td>PM2.5<\/td>\n<td>&lt; 35 &mu;g\/m&sup3;<\/td>\n<td>&lt; 12 &mu;g\/m&sup3;<\/td>\n<\/tr>\n<tr>\n<td>TVOC<\/td>\n<td>&lt; 500 &mu;g\/m&sup3;<\/td>\n<td>&lt; 400 &mu;g\/m&sup3;<\/td>\n<\/tr>\n<tr>\n<td>CO<sub>2<\/sub><\/td>\n<td>&lt; 1,000 ppm<\/td>\n<td>&lt; 600 ppm<\/td>\n<\/tr>\n<tr>\n<td>CO<\/td>\n<td>&lt; 9 ppm (combustion spaces only)<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/table>\n<h2>Certification Mechanics<\/h2>\n<ul>\n<li>Data is streamed to the RESET Assessment Cloud; daily averages must stay within the Acceptable limits for <strong>three consecutive months<\/strong> (the data-review period) for initial certification.<\/li>\n<li>Monitors must be RESET-accredited Grade A (calibration) or Grade B (commercial), wall-mounted in the breathing zone (0.9&ndash;1.8 m), and at least 5 m from operable windows, filters, and fresh-air diffusers.<\/li>\n<li>Results must be shown to occupants via display, app, or QR code &mdash; transparency is part of the intent.<\/li>\n<\/ul>\n<h2>Where Recovery Fits<\/h2>\n<p>RESET does not mandate recovery, but good ventilation is needed to keep CO<sub>2<\/sub> below 1,000 ppm in occupied spaces &mdash; and that ventilation load is exactly what an <a href=\"https:\/\/www.26yc.com\/de\/membrane-energy-recovery-ventilation\/\">ERV&apos;s<\/a> offsets. Filtration (see <a href=\"https:\/\/www.26yc.com\/de\/cleanroom-hvac-heat-recovery\/\">cleanroom HVAC<\/a> practice) supports the PM2.5 target. For the design-side health standard, compare with <a href=\"https:\/\/www.26yc.com\/de\/well-building-standard-ventilation\/\">WELL v2 ventilation<\/a>: RESET is monitoring-first, WELL is design-plus-performance.<\/p>\n<h2>Practical Takeaway<\/h2>\n<p>Because RESET is performance-based, the recovery and filtration system must actually deliver clean air every day, not just on paper. Meter the loops and keep the commissioning records &mdash; the same discipline that <a href=\"https:\/\/www.26yc.com\/de\/iso-50001-heat-recovery\/\">ISO 50001<\/a> demands for energy.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<p><strong>What does RESET Air monitor?<\/strong><br \/>Continuous PM2.5, TVOC, CO2, and CO across at least 80% of occupied space, with temperature and humidity tracked.<\/p>\n<p><strong>What are the RESET performance targets?<\/strong><br \/>For example PM2.5 below 35 micrograms per cubic meter acceptable, CO2 below 1,000 ppm acceptable, with stricter high-performance thresholds.<\/p>\n<p><strong>How is certification achieved?<\/strong><br \/>Monitors stream data to the RESET cloud, and daily averages must stay within acceptable limits for three consecutive months.<\/p>\n<p><strong>Where does heat recovery fit with RESET?<\/strong><br \/>Recovery offsets the ventilation load needed to keep CO2 low, and filtration supports the PM2.5 target; the standard is performance-based, so the system must deliver daily.<\/p>\n<div class=\"yc-related\">\n<h3>Verwandte Artikel<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.26yc.com\/de\/commercial-kitchen-heat-recovery-2\/\" title=\"Commercial Kitchen Heat Recovery\">Commercial Kitchen Heat Recovery<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>RESET Air is the world&rsquo;s first sensor-based, performance-driven indoor-air-quality certification. Its Commercial Interiors v2.0 standard is about continuous monitoring and transparent reporting, not a one-time design check. This article summarizes the monitored parameters and the targets a space must hold. What Gets Monitored RESET requires continuous monitors covering at least 80% of occupants across all [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[197,241],"tags":[174,162],"class_list":["post-4660","post","type-post","status-publish","format-standard","hentry","category-encyclopedia","category-standards-codes","tag-heat-exchanger","tag-heat-recovery"],"_links":{"self":[{"href":"https:\/\/www.26yc.com\/de\/wp-json\/wp\/v2\/posts\/4660","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.26yc.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.26yc.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.26yc.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.26yc.com\/de\/wp-json\/wp\/v2\/comments?post=4660"}],"version-history":[{"count":2,"href":"https:\/\/www.26yc.com\/de\/wp-json\/wp\/v2\/posts\/4660\/revisions"}],"predecessor-version":[{"id":5175,"href":"https:\/\/www.26yc.com\/de\/wp-json\/wp\/v2\/posts\/4660\/revisions\/5175"}],"wp:attachment":[{"href":"https:\/\/www.26yc.com\/de\/wp-json\/wp\/v2\/media?parent=4660"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.26yc.com\/de\/wp-json\/wp\/v2\/categories?post=4660"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.26yc.com\/de\/wp-json\/wp\/v2\/tags?post=4660"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}