{"id":4544,"date":"2026-08-09T20:36:48","date_gmt":"2026-08-10T03:36:48","guid":{"rendered":"https:\/\/www.26yc.com\/data-center-waste-heat-recovery-en\/"},"modified":"2026-10-08T23:36:11","modified_gmt":"2026-10-09T06:36:11","slug":"data-center-waste-heat-recovery-en","status":"publish","type":"post","link":"https:\/\/www.26yc.com\/es\/data-center-waste-heat-recovery-en\/","title":{"rendered":"Por qu\u00e9 los centros de datos apuestan por la recuperaci\u00f3n de calor residual"},"content":{"rendered":"<h2>The Data Center Heat Problem<\/h2>\n<p>Data centers use a large share of the world&#8217;s electricity, and almost all of it ends up as heat. Traditionally that heat is dumped outdoors through cooling towers and chillers. With energy costs climbing, operators are asking a simple question: can that heat be used instead of wasted?<\/p>\n<h2>Two Main Recovery Paths<\/h2>\n<p>La primera v\u00eda es la recuperaci\u00f3n aire-aire. El aire del pasillo caliente pasa por un intercambiador aire-aire de placas o rotativo para calentar el aire fresco entrante o los espacios cercanos. Para la recuperaci\u00f3n sensible en entornos de centro de datos, los intercambiadores de placas y las unidades de evaporaci\u00f3n indirecta (IEC) son la opci\u00f3n com\u00fan. Las ruedas rotativas se evitan generalmente aqu\u00ed por el riesgo de contaminaci\u00f3n cruzada y fuga entre los flujos de suministro y escape.<\/p>\n<p>La segunda v\u00eda es basada en agua. El calor de los servidores se mueve a un lazo de agua y se entrega a redes de calefacci\u00f3n urbana o edificios cercanos. Esto funciona mejor en ciudades densas y fr\u00edas donde hay demanda constante de calor.<\/p>\n<h2>Why the Timing Is Right<\/h2>\n<ul>\n<li>Costos energ\u00e9ticos: cada kilowatt-hora recuperado es uno menos comprado a la red.<\/li>\n<li>Objetivos ESG: reutilizar el calor convierte un flujo de residuo en una victoria de sostenibilidad reportada.<\/li>\n<li>Regulaci\u00f3n: algunas regiones ahora exigen que las grandes instalaciones recuperen o reporten el calor desperdiciado.<\/li>\n<li>Calefacci\u00f3n distrital: las asociaciones con servicios p\u00fablicos hacen pr\u00e1ctica la reutilizaci\u00f3n a escala urbana.<\/li>\n<\/ul>\n<h2>What to Specify<\/h2>\n<p>Para la recuperaci\u00f3n del lado aire, elija intercambiadores de placas o IEC para el calor sensible y mantenga separados los flujos de suministro y escape. Para la recuperaci\u00f3n del lado agua, dimensione lazo para carga parcial en lugar de pico, y prot\u00e9jalo con filtraci\u00f3n adecuada. Cualquiera que sea la v\u00eda, asocie el intercambiador a un medidor para que la energ\u00eda recuperada pueda medirse y reportarse.<\/p>\n<h2>Outlook<\/h2>\n<p>Espere que la recuperaci\u00f3n pase de proyectos piloto a dise\u00f1o predeterminado en nuevas construcciones de centros de datos. A medida que las redes se descarbonizan y la demanda de calor se mantiene alta, convertir el calor residual en un recurso compartido ser\u00e1 uno de los avances m\u00e1s claros de la computaci\u00f3n eficiente.<\/p>\n<div class=\"yc-related\">\n<h3>Art\u00edculos relacionados<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.26yc.com\/es\/hr-vs-erv-differences\/\">HRV vs. ERV: la diferencia que decide el confort de su edificio<\/a><\/li>\n<li><a href=\"https:\/\/www.26yc.com\/es\/data-center-support-space-heat-recovery\/\">Recuperaci\u00f3n de calor en espacios auxiliares de centros de datos: oficinas, laboratorios y muelles<\/a><\/li>\n<li><a href=\"https:\/\/www.26yc.com\/es\/heat-recovery-ventilation-retrofit\/\">Retrofitting Heat Recovery Ventilation into Older Buildings<\/a><\/li>\n<li><a href=\"https:\/\/www.26yc.com\/es\/run-around-coil-design-guide\/\" title=\"Sistemas de bobina en anillo : reglas de dise\u00f1o para corrientes de aire separadas\">Sistemas de bobina en anillo : reglas de dise\u00f1o para corrientes de aire separadas<\/a><\/li>\n<li><a href=\"https:\/\/www.26yc.com\/es\/marine-product-drying-waste-treatment-heat-recovery-unit-corrosion-resistant-stainless-steel\/\" title=\"Marine Product Drying &amp;amp; Waste Treatment Heat Recovery Unit \u2013 Corrosion-Resistant Stainless Steel\">Marine Product Drying &amp;amp; Waste Treatment Heat Recovery Unit \u2013 Corrosion-Resistant Stainless Steel<\/a><\/li>\n<\/ul>\n<\/div>\n<h2>Preguntas frecuentes<\/h2>\n<p><strong>Why recover heat from data centers?<\/strong><br \/>Almost all the electricity a data center draws ends up as heat. Instead of dumping it through chillers and cooling towers, recovery puts that energy to use, cutting the site energy bill and carbon footprint.<\/p>\n<p><strong>What recovery paths exist?<\/strong><br \/>Air-to-air recovery passes hot aisle air through a plate or rotary exchanger to warm incoming air or nearby spaces. Where higher-grade heat is available, heat pumps or Organic Rankine Cycle units can lift it for district heating or power.<\/p>\n<p><strong>Why are rotary wheels often avoided in data centers?<\/strong><br \/>Rotary wheels rotate exhaust and supply through a shared matrix, so a small amount of contaminated exhaust can carry into the clean supply air, a risk most operators avoid in IT spaces.<\/p>\n<p><strong>What can the recovered heat be used for?<\/strong><br \/>Nearby office or lobby heating, domestic hot water, greenhouses, swimming pools, or district heating networks where the data center sits close to heat demand.<\/p>","protected":false},"excerpt":{"rendered":"<p>The Data Center Heat Problem Data centers use a large share of the world&#8217;s electricity, and almost all of it ends up as heat. Traditionally that heat is dumped outdoors through cooling towers and chillers. With energy costs climbing, operators are asking a simple question: can that heat be used instead of wasted? Two Main [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[72,134],"tags":[205,162],"class_list":["post-4544","post","type-post","status-publish","format-standard","hentry","category-heat-recovery","category-news","tag-data-center","tag-heat-recovery"],"_links":{"self":[{"href":"https:\/\/www.26yc.com\/es\/wp-json\/wp\/v2\/posts\/4544","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.26yc.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.26yc.com\/es\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/www.26yc.com\/es\/wp-json\/wp\/v2\/comments?post=4544"}],"version-history":[{"count":3,"href":"https:\/\/www.26yc.com\/es\/wp-json\/wp\/v2\/posts\/4544\/revisions"}],"predecessor-version":[{"id":5231,"href":"https:\/\/www.26yc.com\/es\/wp-json\/wp\/v2\/posts\/4544\/revisions\/5231"}],"wp:attachment":[{"href":"https:\/\/www.26yc.com\/es\/wp-json\/wp\/v2\/media?parent=4544"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.26yc.com\/es\/wp-json\/wp\/v2\/categories?post=4544"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.26yc.com\/es\/wp-json\/wp\/v2\/tags?post=4544"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}