{"id":4544,"date":"2026-08-09T20:36:48","date_gmt":"2026-08-10T03:36:48","guid":{"rendered":"https:\/\/www.26yc.com\/data-center-waste-heat-recovery-en\/"},"modified":"2026-10-08T23:36:11","modified_gmt":"2026-10-09T06:36:11","slug":"data-center-waste-heat-recovery-en","status":"publish","type":"post","link":"https:\/\/www.26yc.com\/zh_cn\/data-center-waste-heat-recovery-en\/","title":{"rendered":"\u6570\u636e\u4e2d\u5fc3\u4e3a\u4f55\u62bc\u6ce8\u5e9f\u70ed\u56de\u6536"},"content":{"rendered":"<h2>The Data Center Heat Problem<\/h2>\n<p>Data centers use a large share of the world&#8217;s electricity, and almost all of it ends up as heat. Traditionally that heat is dumped outdoors through cooling towers and chillers. With energy costs climbing, operators are asking a simple question: can that heat be used instead of wasted?<\/p>\n<h2>Two Main Recovery Paths<\/h2>\n<p>\u7b2c\u4e00\u6761\u8def\u5f84\u662f\u7a7a\u6c14-\u7a7a\u6c14\u56de\u6536\u3002\u70ed\u901a\u9053\u7a7a\u6c14\u901a\u8fc7\u677f\u5f0f\u6216\u65cb\u8f6c\u5f0f\u7a7a\u6c14-\u7a7a\u6c14\u6362\u70ed\u5668\uff0c\u7528\u6765\u52a0\u70ed\u6d41\u5165\u7684\u65b0\u98ce\u6216\u90bb\u8fd1\u7a7a\u95f4\u3002\u6570\u636e\u4e2d\u5fc3\u73af\u5883\u4e0b\u7684\u663e\u70ed\u56de\u6536\uff0c\u677f\u5f0f\u6362\u70ed\u5668\u4e0e\u95f4\u63a5\u84b8\u53d1\uff08IEC\uff09\u673a\u7ec4\u662f\u5e38\u89c1\u9009\u62e9\u3002\u65cb\u8f6c\u8f6e\u56e0\u9001\u98ce\u4e0e\u6392\u98ce\u95f4\u7684\u4ea4\u53c9\u6c61\u67d3\u548c\u6cc4\u6f0f\u98ce\u9669\uff0c\u901a\u5e38\u5728\u6b64\u907f\u7528\u3002<\/p>\n<p>\u7b2c\u4e8c\u6761\u8def\u5f84\u57fa\u4e8e\u6c34\u3002\u670d\u52a1\u5668\u70ed\u91cf\u88ab\u9001\u5165\u6c34\u73af\u8def\uff0c\u8f93\u9001\u5230\u533a\u57df\u4f9b\u70ed\u7f51\u6216\u90bb\u8fd1\u5efa\u7b51\u3002\u8fd9\u5728\u70ed\u9700\u6c42\u7a33\u5b9a\u3001\u4eba\u53e3\u5bc6\u96c6\u7684\u5bd2\u51b7\u57ce\u5e02\u6548\u679c\u6700\u4f73\u3002<\/p>\n<h2>Why the Timing Is Right<\/h2>\n<ul>\n<li>\u80fd\u6e90\u6210\u672c\uff1a\u6bcf\u56de\u65361\u5343\u74e6\u65f6\uff0c\u5c31\u5c11\u4ece\u7535\u7f51\u4e701\u5343\u74e6\u65f6\u3002<\/li>\n<li>ESG \u76ee\u6807\uff1a\u590d\u7528\u70ed\u91cf\u628a\u5e9f\u7269\u6d41\u53d8\u6210\u53ef\u62a5\u544a\u7684\u53ef\u6301\u7eed\u6027\u6210\u679c\u3002<\/li>\n<li>\u76d1\u7ba1\uff1a\u90e8\u5206\u5730\u533a\u5df2\u8981\u6c42\u5927\u578b\u8bbe\u65bd\u56de\u6536\u6216\u62a5\u544a\u5e9f\u70ed\u3002<\/li>\n<li>\u533a\u57df\u4f9b\u70ed\uff1a\u4e0e\u516c\u7528\u4e8b\u4e1a\u5408\u4f5c\u4f7f\u590d\u7528\u5728\u57ce\u5e02\u5c3a\u5ea6\u4e0a\u5207\u5b9e\u53ef\u884c\u3002<\/li>\n<\/ul>\n<h2>What to Specify<\/h2>\n<p>\u7a7a\u6c14\u4fa7\u56de\u6536\uff1a\u9009\u62e9\u677f\u5f0f\u6362\u70ed\u5668\u6216 IEC \u56de\u6536\u663e\u70ed\uff0c\u5e76\u4fdd\u6301\u9001\u98ce\u4e0e\u6392\u98ce\u9694\u79bb\u3002\u6c34\u4fa7\u56de\u6536\uff1a\u6309\u90e8\u5206\u8d1f\u8377\u800c\u975e\u5cf0\u503c\u8bbe\u8ba1\u73af\u8def\uff0c\u5e76\u4ee5\u9002\u5f53\u8fc7\u6ee4\u4fdd\u62a4\u3002\u65e0\u8bba\u54ea\u6761\u8def\u5f84\uff0c\u90fd\u5e94\u7ed9\u6362\u70ed\u5668\u914d\u4e0a\u8ba1\u91cf\uff0c\u4ee5\u4fbf\u6d4b\u91cf\u5e76\u62a5\u544a\u56de\u6536\u80fd\u91cf\u3002<\/p>\n<h2>Outlook<\/h2>\n<p>\u9884\u671f\u56de\u6536\u5c06\u4ece\u8bd5\u70b9\u9879\u76ee\u8d70\u5411\u65b0\u5efa\u6570\u636e\u4e2d\u5fc3\u7684\u9ed8\u8ba4\u8bbe\u8ba1\u3002\u968f\u7740\u7535\u7f51\u66f4\u6e05\u6d01\u3001\u70ed\u9700\u6c42\u5c45\u9ad8\u4e0d\u4e0b\uff0c\u628a\u5e9f\u70ed\u53d8\u6210\u5171\u4eab\u8d44\u6e90\u5c06\u662f\u9ad8\u6548\u8ba1\u7b97\u6700\u660e\u786e\u7684\u8d62\u9762\u4e4b\u4e00\u3002<\/p>\n<div class=\"yc-related\">\n<h3>\u76f8\u5173\u6587\u7ae0<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.26yc.com\/zh_cn\/hr-vs-erv-differences\/\">HRV \u4e0e ERV\uff1a\u51b3\u5b9a\u5efa\u7b51\u8212\u9002\u5ea6\u7684\u5173\u952e\u5dee\u5f02<\/a><\/li>\n<li><a href=\"https:\/\/www.26yc.com\/zh_cn\/data-center-support-space-heat-recovery\/\">\u6570\u636e\u4e2d\u5fc3\u914d\u5957\u7a7a\u95f4\u70ed\u56de\u6536\uff1a\u529e\u516c\u5ba4\u3001\u5b9e\u9a8c\u5ba4\u4e0e\u88c5\u5378\u533a<\/a><\/li>\n<li><a href=\"https:\/\/www.26yc.com\/zh_cn\/heat-recovery-ventilation-retrofit\/\">Retrofitting Heat Recovery Ventilation into Older Buildings<\/a><\/li>\n<li><a href=\"https:\/\/www.26yc.com\/zh_cn\/run-around-coil-design-guide\/\" title=\"\u7ed5\u7ba1\u5f0f\u76d8\u7ba1\u7cfb\u7edf\uff1a\u5206\u79bb\u6c14\u6d41\u7684\u8bbe\u8ba1\u89c4\u5219\">\u7ed5\u7ba1\u5f0f\u76d8\u7ba1\u7cfb\u7edf\uff1a\u5206\u79bb\u6c14\u6d41\u7684\u8bbe\u8ba1\u89c4\u5219<\/a><\/li>\n<li><a href=\"https:\/\/www.26yc.com\/zh_cn\/marine-product-drying-waste-treatment-heat-recovery-unit-corrosion-resistant-stainless-steel\/\" title=\"Marine Product Drying &amp;amp; Waste Treatment Heat Recovery Unit \u2013 Corrosion-Resistant Stainless Steel\">Marine Product Drying &amp;amp; Waste Treatment Heat Recovery Unit \u2013 Corrosion-Resistant Stainless Steel<\/a><\/li>\n<\/ul>\n<\/div>\n<h2>\u5e38\u89c1\u95ee\u9898<\/h2>\n<p><strong>Why recover heat from data centers?<\/strong><br \/>Almost all the electricity a data center draws ends up as heat. Instead of dumping it through chillers and cooling towers, recovery puts that energy to use, cutting the site energy bill and carbon footprint.<\/p>\n<p><strong>What recovery paths exist?<\/strong><br \/>Air-to-air recovery passes hot aisle air through a plate or rotary exchanger to warm incoming air or nearby spaces. Where higher-grade heat is available, heat pumps or Organic Rankine Cycle units can lift it for district heating or power.<\/p>\n<p><strong>Why are rotary wheels often avoided in data centers?<\/strong><br \/>Rotary wheels rotate exhaust and supply through a shared matrix, so a small amount of contaminated exhaust can carry into the clean supply air, a risk most operators avoid in IT spaces.<\/p>\n<p><strong>What can the recovered heat be used for?<\/strong><br \/>Nearby office or lobby heating, domestic hot water, greenhouses, swimming pools, or district heating networks where the data center sits close to heat demand.<\/p>","protected":false},"excerpt":{"rendered":"<p>The Data Center Heat Problem Data centers use a large share of the world&#8217;s electricity, and almost all of it ends up as heat. Traditionally that heat is dumped outdoors through cooling towers and chillers. With energy costs climbing, operators are asking a simple question: can that heat be used instead of wasted? Two Main [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[72,134],"tags":[205,162],"class_list":["post-4544","post","type-post","status-publish","format-standard","hentry","category-heat-recovery","category-news","tag-data-center","tag-heat-recovery"],"_links":{"self":[{"href":"https:\/\/www.26yc.com\/zh_cn\/wp-json\/wp\/v2\/posts\/4544","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.26yc.com\/zh_cn\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.26yc.com\/zh_cn\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/www.26yc.com\/zh_cn\/wp-json\/wp\/v2\/comments?post=4544"}],"version-history":[{"count":3,"href":"https:\/\/www.26yc.com\/zh_cn\/wp-json\/wp\/v2\/posts\/4544\/revisions"}],"predecessor-version":[{"id":5231,"href":"https:\/\/www.26yc.com\/zh_cn\/wp-json\/wp\/v2\/posts\/4544\/revisions\/5231"}],"wp:attachment":[{"href":"https:\/\/www.26yc.com\/zh_cn\/wp-json\/wp\/v2\/media?parent=4544"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.26yc.com\/zh_cn\/wp-json\/wp\/v2\/categories?post=4544"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.26yc.com\/zh_cn\/wp-json\/wp\/v2\/tags?post=4544"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}