Heat Recovery Standards and Certifications

When you specify or buy a heat recovery unit, third-party standards tell you the numbers are comparable and real. Knowing the key marks helps avoid inflated claims. Testing Standards AHRI 1060: North American rating method for air-to-air heat exchangers. EN 308: European test method for heat transfer in recovery components. ISO 16494: International method for […]

Building Code Heat Recovery Mandate

Across jurisdictions, building codes increasingly mandate energy recovery once a system serves enough outdoor air. This overview compares the main regimes so a designer can specify one core that clears them all. Minimum Effectiveness by Regime Regime Trigger Minimum recovery ASHRAE 90.1-2022 (US) ≥ 5,000 CFM and ≥ 70% OA 50% enthalpy (AHRI 1060) IECC […]

IECC Energy Recovery Provisions

The International Energy Conservation Code (IECC) is updated on a three-year cycle (2018, 2021, 2024) and is adopted — with or without amendments — by most U.S. states. Its commercial energy-recovery rule lives in Section C403.7, and it is the baseline that many state codes reference. This article summarizes the C403.7 trigger and how the […]

WELL Building Standard Ventilation

The WELL Building Standard v2 (IWBI) is a performance standard for occupant health, and ventilation is one of its strongest levers. Where energy codes set a floor for “acceptable” air, WELL rewards going well beyond it. This article covers the Air Concept features most relevant to recovery and ventilation design. Feature A06 — Enhanced Ventilation […]

RESET Air Standard

RESET Air is the world’s first sensor-based, performance-driven indoor-air-quality certification. Its Commercial Interiors v2.0 standard is about continuous monitoring and transparent reporting, not a one-time design check. This article summarizes the monitored parameters and the targets a space must hold. What Gets Monitored RESET requires continuous monitors covering at least 80% of occupants across all […]

WELL v2 Performance Verification for Air and Thermal Comfort

WELL v2 and Performance Verification The WELL Building Standard v2 (IWBI) certifies buildings on a points basis across ten concepts. Unlike a one-time design review, WELL requires Performance Verification, on-site or post-occupancy testing of selected features before certification is awarded and at recertification. What Gets Verified Air (A01 to A09): particulate PM2.5 and PM10, TVOC, […]

EU F-Gas Regulation 2024/573: Refrigerant Phase-Down and Low-GWP Alternatives

Regulation (EU) 2024/573 The EU F-Gas Regulation 2024/573 entered into force on 11 March 2024, repealing 517/2014. It drives HFC availability to zero by 2050 through a tightening CO2-equivalent quota schedule, high-GWP refrigerants consume quota faster, pushing the market to low-GWP alternatives. Key Placing-on-Market Bans Equipment Ban Date Single splits under 3 kg GWP 750 […]

Empieza a escribir tu término de búsqueda arriba y pulsa Intro para buscar. Pulsa Esc para cancelar.

Volver arriba