China Fresh Air (ERV/HRV) Ventilation Industry: Hubs and Market Status

Market Scale and Headroom China’s fresh-air (ventilation with energy recovery, ERV/HRV) market reached roughly RMB 40-60 billion in 2024, depending on whether installation and accessories are included. Penetration sits around 12%, far below the 40%+ seen in Europe and North America – leaving substantial long-term headroom as health-awareness and building codes tighten. Manufacturing Hubs Guangdong […]

デシカントローター vs エネルギー回収ローター:使い分け

Energy recovery wheel Transfers both sensible and (if enthalpic) latent heat between supply and exhaust air. Goal: cut HVAC heating/cooling load. Made of aluminum or polymer matrix, sometimes with a moisture-absorbing coating. Desiccant wheel Impregnated or coated with a desiccant (silica gel, molecular sieve, or zeolite). Its job is dehumidification – it pulls moisture from […]

エネルギー回収ローターのトラブルシューティング:一般的な故障と修理

Low effectiveness Cause: wheel not rotating (motor or belt failure), or condensate/fouling blocking the matrix.Fix: verify rotation and speed; wash the wheel with low-pressure water and a mild detergent; confirm belt tension. Frost or ice buildup (cold climates) Cause: exhaust-side temperature dropping below freezing.Fix: enable purge sector, reduce speed, or add preheat. See frost protection […]

空港HVAC&エネルギー回収:ターミナル消費エネルギーの削減

Why terminals are energy hotspots Airports are among the most energy-intensive buildings in the commercial sector. Vast terminals run 24/7 with high fresh-air requirements, large glass facades, and constantly moving passenger loads. Heating and cooling the ventilation air alone can account for 40-60% of a terminal’s HVAC energy. Air-to-air heat recovery is the single highest-return […]

IECC Energy Recovery Provisions

The International Energy Conservation Code (IECC) is updated on a three-year cycle (2018, 2021, 2024) and is adopted — with or without amendments — by most U.S. states. Its commercial energy-recovery rule lives in Section C403.7, and it is the baseline that many state codes reference. This article summarizes the C403.7 trigger and how the […]

IECC 2024: Energy Recovery Ventilation Provisions Explained

IECC 2024 and the Energy Recovery Link The 2024 International Energy Conservation Code (IECC) addresses commercial ventilation largely by reference to ASHRAE 62.1-2022. Because 62.1 already requires energy recovery on many large outdoor-air systems, IECC 2024 indirectly tightens ERV expectations, in Climate Zones 4 to 8 an energy recovery ventilator is commonly required where a […]