Dew Point and Frost Point: The Temperatures That Decide Core Survival

Dew point: where water appears

The dew point is the temperature at which air, cooled at constant pressure and humidity, becomes saturated and water begins to condense. If a recovery core surface drops below the exhaust dew point, condensate forms on it – normal in cooling duty, a design input for drainage.

Frost point: where ice appears

Below 0 degC the same limit is the frost point: moisture deposits as ice instead of liquid. In cold-climate ventilation the exhaust airstream can sit below freezing while the supply is also cold, so the core can ice up and block airflow.

Why this bounds the design

Recovery only works while the core is open. Once frost bridges the channels, effectiveness collapses and fan power spikes. That is why 基于气候的选型 matters: northern sites need defrost or frost-tolerant cores, not just a high nominal effectiveness.

Related reading

Protection strategies – purge sectors, preheat, bypass – are covered separately under frost protection in heat recovery systems.

Frequently asked questions

Is frost point always below dew point? For the same moisture content, yes – frost forms at a lower temperature than condensation because ice has lower vapour pressure than liquid water.

Do plates frost as badly as wheels? Plates can frost too, but a motorised bypass is simpler to apply than wheel regeneration.

Need help specifying the right air-to-air heat recovery for your project? Contact the QIYU engineering team – WhatsApp +86 157 5335 5505, or email kuns913@gmail.com.

常见问题

Why is dew point the critical temperature for a recuperator?

When the colder exhaust falls below the incoming air's dew point, moisture condenses on the core; below 0 degrees C it can frost and block the passages, so dew and frost point set the defrost or bypass strategy.

How do you protect a core in freezing climates?

Use frost-suppression methods such as preheating the supply air, recirculation or bypass of part of the exhaust, or wheel frost-control purging so the leaving-exhaust temperature stays above freezing.

常见问题

Why is dew point the critical temperature for a recuperator?

When the colder exhaust falls below the incoming air's dew point, moisture condenses on the core; below 0 degrees C it can frost and block the passages, so dew and frost point set the defrost or bypass strategy.

How do you protect a core in freezing climates?

Use frost-suppression methods such as preheating the supply air, recirculation or bypass of part of the exhaust, or wheel frost-control purging so the leaving-exhaust temperature stays above freezing.

选型合适的换热器

我们的工程师会根据您的风量、温度和压降预算设计芯体,并按应用选择板式、旋转式或热管回收。阅读 换热器指南 ,或联系我们获取规格书。

询价

相关产品

Air-to-Air Heat Exchanger

面向暖通空调与通风的板式、旋转式或热管回收。

Plate Heat Exchanger

空气与液体用大表面积固定芯体。

旋转热回收轮

大风量用高效能量回收。

Heat Pipe Heat Exchanger

用于洁净场合的被动、完全分离气流。

相关文章

开始在上面输入您的搜索词,然后按回车进行搜索。按ESC取消。

返回顶部
免费热回收计算器及选型工具