Precalentamiento de aire geotérmico y de fuente subterránea

The earth a few meters below the surface stays near constant temperature all year. That stable thermal mass can be used to pre-condition ventilation air before it reaches a building, cutting heating and cooling loads.

How Ground Coupling Works

Outdoor air is passed through a buried pipe loop (ground heat exchanger) or across a ground-coupled coil. In winter the ground warms the incoming air; in summer it cools it. The air-to-air exchanger then fine-tunes the temperature using building exhaust.

Two Common Approaches

  • Earth-air heat exchanger (EAHX): A network of buried pipes that tempers fresh air directly. Simple, no refrigerant.
  • Ground-source heat pump (GSHP) + recovery: A heat pump upgrades ground energy; an air-to-air core recovers exhaust heat for additional savings.

Where It Pays Off

  • Extreme climates with large seasonal swings
  • Buildings with high fresh-air requirements (schools, labs)
  • Passive or near-zero-energy building projects
  • Greenhouses and agricultural facilities

Design Cautions

  • Pipe depth and length must match airflow and soil type.
  • Avoid placing intakes near contaminant sources (septic, fuel tanks).
  • Condensation in the buried pipe needs a drain or slope.
  • Combine with a plate or heat-pipe core for best year-round performance.

Preguntas frecuentes

Does the ground freeze in winter?
Below ~2 m the temperature is stable and rarely freezes; the top few meters provide the seasonal buffering.

Is it worth the excavation cost?
For large, continuous ventilation loads it often pays back in 3-6 years; for small buildings the air-to-air core alone is usually enough.

Preguntas frecuentes

Does the ground freeze in winter?

Below ~2 m the temperature is stable and rarely freezes; the top few meters provide the seasonal buffering.

Is it worth the excavation cost?

For large, continuous ventilation loads it often pays back in 3-6 years; for small buildings the air-to-air core alone is usually enough.

Especifique el intercambiador adecuado

Nuestros ingenieros dimensionan el núcleo según su caudal, temperatura y presupuesto de caída de presión, y seleccionan recuperación por placa, rotativa o caloduc según la aplicación. Lea la guía del intercambiador , o contáctenos para una especificación.

Solicitar cotización

Productos relacionados

Air-to-Air Heat Exchanger

Recuperación por placa, rotativa o caloduc para HVAC y ventilación.

Plate Heat Exchanger

Núcleos estacionarios de gran superficie para aire y líquido.

rueda de recuperación rotativa

Recuperación de energía de alta eficacia para grandes caudales.

Heat Pipe Heat Exchanger

Corrientes pasivas y totalmente separadas para aplicaciones limpias.

Publicaciones relacionadas

Empieza a escribir tu término de búsqueda arriba y pulsa Intro para buscar. Pulsa Esc para cancelar.

Volver arriba
Calculadoras gratuitas de recuperación de calor y herramientas de dimensionamiento