When You Need HEPA/ULPA
Any space that must control sub-micron particles-cleanrooms, operating theatres, aseptic pharma, microelectronics, biosafety labs-uses H10-H14 (HEPA) or U15-U17 (ULPA) rated by EN 1822 MPPS efficiency.
Build Types
- Mini-pleat (separatorless) – hot-melt bead spacers, deep pleats, low ΔP; the modern standard.
- Separator (paper corrugated) – aluminium/paper separators, robust; traditional box builds.
- Box / ceiling terminals – factory-sealed flanges for cleanroom ceilings; often H13/H14.
- Gel-seal – knife-edge into a gel track for leak-free critical installs.
Typical Specifications
| Class | MPPS efficiency | Initial ΔP | Typical space |
|---|---|---|---|
| H13 | 99.95% | 120-200 Pa | OR, ISO 5, aseptic |
| H14 | 99.995% | 150-250 Pa | ISO 5 critical |
| U15 | 99.9995% (≥0.12 µm) | 200-300 Pa | ULPA ISO 3-4 |
Selection Checklist
- Match class to the cleanroom ISO grade (H13/H14 for ISO 5; U15+ for tighter).
- Specify leakage test (scan) and a frame/seal method (gel, knife, gasket).
- Confirm max temperature and humidity limits of the media.
- Plan PAO/DOP integrity testing at install and annually.
.yc-spec-wrap{margin:36px 0 28px}
.yc-spec-wrap figure{margin:0 0 24px;text-align:center}
.yc-spec-wrap figure img{max-width:100%;height:auto;border:1px solid #e5e7eb;border-radius:8px}
.yc-spec-wrap figcaption{font-size:14px;color:#6b7280;margin-top:8px}
.yc-spec{width:100%;border-collapse:collapse;font-size:15px;margin:8px 0 16px}
.yc-spec th,.yc-spec td{border:1px solid #d1d5db;padding:9px 12px;text-align:left;vertical-align:top}
.yc-spec th{background:#1f3a5f;color:#fff}
.yc-spec tr:nth-child(even) td{background:#f8fafc}
.yc-note{font-size:14px;color:#6b7280;margin-top:4px}
.yc-thumb-row{display:flex;gap:16px;flex-wrap:wrap;margin:0 0 20px}
.yc-thumb-row figure{flex:1 1 240px;margin:0;text-align:center}
Model Range & Specifications

| Model | EN 1822 class | MPPS efficiency | Construction | Typical initial ΔP | Final ΔP (replace) |
|---|---|---|---|---|---|
| 26YC-HP-H11 | H11 | ≥ 95% | Minipleat, aluminium frame, 78–292 mm | 100–140 Pa | 450–600 Pa |
| 26YC-HP-H12 | H12 | ≥ 99.5% | Minipleat, aluminium frame, 150–292 mm | 140–180 Pa | |
| 26YC-HP-H13 | H13 | ≥ 99.95% | Minipleat, aluminium frame, 220–292 mm | 200–250 Pa | |
| 26YC-HP-H14 | H14 | ≥ 99.995% | Minipleat, aluminium frame, 292 mm | 230–280 Pa | |
| 26YC-UL-U15 | U15 | ≥ 99.9995% | ULPA minipleat, aluminium frame, 292 mm | 250–300 Pa |
Standard face sizes 610 × 610 mm and 610 × 762 mm, rated 1 000–1 700 m³/h; aluminium-separator versions for high-temperature duty (up to 250 °C with special sealant and frame); every filter individually scanned and tested to EN 1822 with certificate supplied. PU or silicone gaskets, custom sizes on request.