U-Value: The Building-Side Recovery Metric

Definition

The U-value is the rate of heat transfer through a building element per square metre per degree of temperature difference, in W/m2.K. A low-U wall or window loses little heat; a high-U one loses a lot.

U-value vs the exchanger k-value

Do not confuse them. The exchanger overall conductance (UxA in the epsilon-NTU method) describes the recovery core; the building U-value describes the envelope. They meet at the load calculation: better envelope (lower U) means less heating demand, which both cuts energy and changes how much recovery is worth recovering.

Why recovery still matters with a good envelope

Even a Passive House with very low U-value still ventilates (see Passive House recovery), and that ventilation air is the dominant remaining load. Decarbonisation strategies pair a tight envelope with high-effectiveness recovery so the ventilation load – not the walls – is what gets addressed.

Frequently asked questions

Does better insulation remove the need for recovery? No – it shifts the largest load to ventilation air, which only recovery addresses.

Is lower U always better? Up to a point; beyond code, the marginal cost often beats the marginal energy saving.

Need help specifying the right air-to-air heat recovery for your project? Contact the QIYU engineering team – WhatsApp +86 157 5335 5505, or email kuns913@gmail.com.

Questions fréquemment posées

What is U-value?

U-value is the rate of heat transfer through a building element per square metre per degree of temperature difference, in W per m2 per K; lower means better insulation.

How does recovery relate to U-value?

Recovery reduces the ventilation load that the building envelope U-value would otherwise have to compensate for; together they set the total heating and cooling demand.

Questions fréquemment posées

What is U-value?

U-value is the rate of heat transfer through a building element per square metre per degree of temperature difference, in W per m2 per K; lower means better insulation.

How does recovery relate to U-value?

Recovery reduces the ventilation load that the building envelope U-value would otherwise have to compensate for; together they set the total heating and cooling demand.

Spécifiez le bon échangeur

Nos ingénieurs dimensionnent le noyau selon votre débit, température et budget de perte de charge, et choisissent la récupération par plaque, rotative ou caloduc selon l'application. Lisez le guide de l'échangeur , ou contactez-nous pour une spécification.

Demander un devis

Produits connexes

Air-to-Air Heat Exchanger

Récupération par plaque, rotative ou caloduc pour le CVC et la ventilation.

Plate Heat Exchanger

Noyaux stationnaires à grande surface pour l'air et le liquide.

roue de récupération rotative

Récupération d'énergie à haute efficacité pour grands débits.

Heat Pipe Heat Exchanger

Courants passifs et totalement séparés pour applications propres.

Articles similaires

Commencez à saisir votre recherche ci-dessus et pressez Entrée pour rechercher. ESC pour annuler.

Retour en haut
Calculateurs gratuits de récupération de chaleur et outils de dimensionnement