California Title 24, Part 6 (the Building Energy Efficiency Standards) is the most aggressive state energy code in the U.S., and its 2022 edition — effective 1 January 2023, with a July 2024 Supplement — puts heat recovery at the center of both nonresidential and multifamily compliance. This article distills the recovery provisions that trigger […]
Préchauffage de l'air géothermique et par source souterraine
The earth a few meters below the surface stays near constant temperature all year. That stable thermal mass can be used to pre-condition ventilation air before it reaches a building, cutting heating and cooling loads. How Ground Coupling Works Outdoor air is passed through a buried pipe loop (ground heat exchanger) or across a ground-coupled […]
Récupération de chaleur des échappements pharmaceutiques et de salles blanches
Pharmaceutical plants and cleanrooms move huge volumes of HEPA-filtered air. Codes generally forbid recirculating exhaust that may carry contaminants, but the energy in that air can still be recovered using physically separated exchangers. Why Separation Is Mandatory GMP and HVAC codes require exhaust from containment areas to be discharged, not reused. Cross-contamination could compromise product […]
Récupération de chaleur pour cuisines commerciales
Commercial kitchens run powerful hoods that throw away large amounts of hot, greasy air. Replacing it with conditioned make-up air is a major cost. Kitchen heat recovery captures the sensible heat while keeping grease and smoke out of the supply. Why Separation Matters in Kitchens Exhaust carries grease aerosol and odors, so any recovery device […]
Guide de nettoyage et d'entretien des échangeurs de chaleur
Heat recovery equipment only delivers its rated savings if it stays clean. Dust, grease, and moisture film raise pressure drop and lower effectiveness. A simple maintenance plan protects the investment. General Inspection Schedule Environment Inspect Clean Clean office air Every 6 months Annually Dusty / industrial Quarterly When dP +15-20 % Greasy (kitchen, booth) Monthly […]
Récupération air-air vs air-eau
Heat recovery comes in two broad forms. Air-to-air exchangers move heat directly between two air streams. Air-to-water devices (like run-around coils or exhaust water heaters) transfer heat into a fluid loop that can serve distant or mixed loads. Side-by-Side Factor Air-to-Air Air-to-Water Streams Two air ducts Air + water/glycol loop Distance Short (cores co-located) Long […]
Protection contre le givre dans les systèmes de récupération
In cold climates, exhaust air can be warm and humid while intake is far below freezing. When that exhaust cools below its dew point inside the core, frost forms. Left unchecked, ice blocks the airflow entirely. Why Frost Happens Frost appears when exhaust outlet temperature drops near 0 C and the core surface is below […]
Normes et certifications de récupération de chaleur
When you specify or buy a heat recovery unit, third-party standards tell you the numbers are comparable and real. Knowing the key marks helps avoid inflated claims. Testing Standards AHRI 1060: North American rating method for air-to-air heat exchangers. EN 308: European test method for heat transfer in recovery components. ISO 16494: International method for […]
Calcul du retour de la récupération de chaleur
Before buying a recovery unit, a quick payback calculation shows whether it makes sense. You only need a few field numbers and the local energy price. The Core Formula Annual energy saved (kWh) = 1.2 x airflow (m3/h) x eta x dT (C) x hours/year / 1000 Where 1.2 is the approximate volumetric heat capacity […]
Choisir un échangeur de chaleur pour un retrofit HVAC
Retrofitting heat recovery into an existing building is different from designing new. Space, duct layout, and control integration usually drive the choice more than peak efficiency. Step 1: Audit the Air Streams Confirm there is a dedicated exhaust and a matching supply. Measure airflow (m³/h or CFM) and temperature profiles. Note operating hours — recovery […]