“We are certified” is the most repeated — and most abused — phrase in Chinese HVAC exports. Here is how to verify it before you pay. CE marking A bare CE sticker is often a self-declaration (Module A) and proves little. For pressurised plate exchangers, ask whether the supplier complies with the Pressure Equipment Directive […]
AHRI 1060: Rating Air-to-Air Energy Recovery Ventilation Equipment
What AHRI 1060 Covers AHRI 1060 is the Air-Conditioning, Heating, and Refrigeration Institute standard that rates air-to-air energy recovery ventilation (ERV) and heat recovery ventilation (HRV) equipment. It defines how manufacturers must test and report the performance that buyers actually compare: sensible effectiveness, total (enthalpy) effectiveness, rated airflow, external static pressure, and supply- and exhaust-side […]
EN 308: Test Procedures for Air-to-Air Heat Transfer in Recovery Equipment
Purpose of EN 308 EN 308 is the European standard that specifies test procedures for air-to-air heat transfer in heat recovery equipment. Rather than setting a pass/fail threshold, it defines how to measure temperature effectiveness and, for enthalpy devices, moisture effectiveness under controlled inlet conditions. What Gets Measured The test fixes inlet dry-bulb temperatures and, […]
GB/T 21087: China’s Standard for Air-to-Air Energy Recovery Devices
Scope of GB/T 21087 GB/T 21087 is China’s national standard for air-to-air energy recovery devices. It covers the common recovery types used in Chinese and exported equipment: plate (recuperative), rotary wheel (regenerative), heat-pipe, and run-around coil systems. What It Specifies The standard defines classification, technical requirements, test methods, inspection rules, and marking or labeling. It […]
EN 16798: Ventilation Requirements and Energy Recovery in Buildings
What EN 16798 Covers The EN 16798 series (which replaced EN 15251) sets the framework for indoor environmental quality and the energy performance of ventilation and building services. It defines how much ventilation is needed and, through the accompanying energy requirements, when recovery is effectively mandatory. Energy Recovery in the Standard Where outdoor-air rates are […]
Eurovent Certification for Energy Recovery Equipment
What Eurovent Certification Is Eurovent certification is an independent, third-party verification that a manufacturer’s published energy-recovery performance matches tested results. Certified products appear in a public directory with their verified ratings. Why It Reduces Risk Recovery effectiveness is easy to overstate in a brochure. Certification against a method such as EN 308 gives buyers a […]
How to Read an Air-to-Air Heat Exchanger Test Report
Start With the Test Standard First confirm which standard the report uses — AHRI 1060 or EN 308. The method defines the conditions, so a number from one standard is not directly comparable to a number from another. Sensible vs Total Effectiveness Read both sensible (temperature) and total (enthalpy) effectiveness. A plate exchanger only reports […]
China Dual-Carbon (3060) Policy as a Driver for Heat Recovery
The 3060 Commitments China has pledged to peak carbon dioxide emissions before 2030 and achieve carbon neutrality before 2060 (the ‘Dual Carbon’ or 3060 goals). Meeting them hinges on industrial energy efficiency – and waste-heat / recovery equipment sits squarely in the toolbox. Key Policy Documents 2024-2025 Energy Conservation and Carbon Reduction Action Plan (State […]
Thermal Comfort and Heat Recovery: ASHRAE 55 and IEQ
ASHRAE 55 and Thermal Comfort ASHRAE 55 defines acceptable thermal environments through the PMV or PPD model, balancing air temperature, mean radiant temperature, humidity, air speed and clothing. Heat recovery changes supply-air conditions, so it must be designed without degrading comfort. Humidity and IEQ Enthalpy recovery transfers moisture as well as heat, helping hold indoor […]
California Title 24 Heat Recovery
California Title 24, Part 6 (the Building Energy Efficiency Standards) is the most aggressive state energy code in the U.S., and its 2022 edition — effective 1 January 2023, with a July 2024 Supplement — puts heat recovery at the center of both nonresidential and multifamily compliance. This article distills the recovery provisions that trigger […]