Membrane Air Conditioning Systems

Membrane air conditioning systems separate the sensible and latent cooling loads using a liquid-desiccant loop and a membrane contactor, rather than a single overcooling coil. The result is drier supply air at a higher coil evaporating temperature — which raises the chiller COP.

Core Components

A typical unit pairs a membrane energy recovery ventilation core with a desiccant regenerator. The air-side hardware follows standard AHU components: fans, filters, coils, and the membrane module.

Why Higher Evaporating Temperature Helps

  • Less compressor lift → higher COP.
  • Less reheat energy because the coil no longer overcools.
  • Better control of supply RH independent of supply temperature.

Where It Pays Back

Building type Benefit
Humid-climate offices Large latent load, strong fit
Laboratories See laboratory heat recovery
Dry climates Marginal — use sensible recovery

For sizing the air handler around a membrane module, use the method in AHU selection calculation. Membrane AC is best viewed as an extension of total-energy recovery, not a replacement for it.

Putting the Pieces Together

In practice a membrane AC system is a packaged air handler: outdoor and return air pass through the membrane contactor where a liquid desiccant pulls moisture out of the supply stream, while a separate sensible recovery core handles the temperature side. The desiccant is then regenerated, ideally with recovered heat, and circulated in a closed loop. Because the cooling coil now deals only with sensible load at a higher evaporating temperature, the chiller or DX plant runs fewer compressors and reaches a better COP. Controls must coordinate three loops, supply temperature, supply humidity, and desiccant concentration, so a modest building-management sequence is needed. Retrofit cases usually keep the existing coils and add the membrane module and desiccant circuit, which limits capital outlay. The approach suits humid-climate offices and labs most, where latent load dominates; in dry climates the added complexity rarely pays back versus plain sensible recovery.

よくある質問

How does a membrane air-conditioning system raise chiller COP?
By removing latent load with a desiccant loop at a higher coil evaporating temperature, which reduces compressor lift.

What are the main components?
A membrane contactor, a liquid-desiccant regenerator, a sensible recovery core, and the standard AHU fans, filters, and coils.

Is membrane AC a replacement for energy recovery?
No. It is best viewed as an extension of total-energy recovery that handles the latent load a basic core does not.

Where does membrane AC pay back best?
In humid-climate offices and laboratories with large latent loads; dry climates see marginal benefit versus plain sensible recovery.

よくある質問

How does a membrane air-conditioning system raise chiller COP?

By removing latent load with a desiccant loop at a higher coil evaporating temperature, which reduces compressor lift.

What are the main components?

A membrane contactor, a liquid-desiccant regenerator, a sensible recovery core, and the standard AHU fans, filters, and coils.

Is membrane AC a replacement for energy recovery?

No. It is best viewed as an extension of total-energy recovery that handles the latent load a basic core does not.

Where does membrane AC pay back best?

In humid-climate offices and laboratories with large latent loads; dry climates see marginal benefit versus plain sensible recovery.

適切な熱交換器を選定

当社のエンジニアが風量、温度、圧力損失の予算に合わせてコアを設計し、用途に応じて板式・回転式・ヒートパイプ回収を選定します。以下をお読みください: 熱交換器ガイド 、または仕様についてお問い合わせください。

見積りを依頼

関連製品

Air-to-Air Heat Exchanger

HVAC および換気向けの板式・回転式・ヒートパイプ回収。

Plate Heat Exchanger

空気と液体用の大表面積固定コア。

ロータリー熱回収ホイール

大風量向け高効率エネルギー回収。

Heat Pipe Heat Exchanger

清浄用途向けの受動的・完全分離流。

関連投稿

検索語を上に入力し、 Enter キーを押して検索します。キャンセルするには ESC を押してください。

トップに戻る
無料の熱回収計算ツールおよびサイジングツール