Thermal Comfort and Heat Recovery: ASHRAE 55 and IEQ

ASHRAE 55 and Thermal Comfort ASHRAE 55 defines acceptable thermal environments through the PMV or PPD model, balancing air temperature, mean radiant temperature, humidity, air speed and clothing. Heat recovery changes supply-air conditions, so it must be designed without degrading comfort. Humidity and IEQ Enthalpy recovery transfers moisture as well as heat, helping hold indoor […]

熱回収の規格と認証

When you specify or buy a heat recovery unit, third-party standards tell you the numbers are comparable and real. Knowing the key marks helps avoid inflated claims. Testing Standards AHRI 1060: North American rating method for air-to-air heat exchangers. EN 308: European test method for heat transfer in recovery components. ISO 16494: International method for […]

建築基準法の熱回収義務

Across jurisdictions, building codes increasingly mandate energy recovery once a system serves enough outdoor air. This overview compares the main regimes so a designer can specify one core that clears them all. Minimum Effectiveness by Regime Regime Trigger Minimum recovery ASHRAE 90.1-2022 (US) ≥ 5,000 CFM and ≥ 70% OA 50% enthalpy (AHRI 1060) IECC […]

IECC Energy Recovery Provisions

The International Energy Conservation Code (IECC) is updated on a three-year cycle (2018, 2021, 2024) and is adopted — with or without amendments — by most U.S. states. Its commercial energy-recovery rule lives in Section C403.7, and it is the baseline that many state codes reference. This article summarizes the C403.7 trigger and how the […]

WELL Building Standard Ventilation

The WELL Building Standard v2 (IWBI) is a performance standard for occupant health, and ventilation is one of its strongest levers. Where energy codes set a floor for “acceptable” air, WELL rewards going well beyond it. This article covers the Air Concept features most relevant to recovery and ventilation design. Feature A06 — Enhanced Ventilation […]

RESET Air Standard

RESET Air is the world’s first sensor-based, performance-driven indoor-air-quality certification. Its Commercial Interiors v2.0 standard is about continuous monitoring and transparent reporting, not a one-time design check. This article summarizes the monitored parameters and the targets a space must hold. What Gets Monitored RESET requires continuous monitors covering at least 80% of occupants across all […]

IECC 2024: Energy Recovery Ventilation Provisions Explained

IECC 2024 and the Energy Recovery Link The 2024 International Energy Conservation Code (IECC) addresses commercial ventilation largely by reference to ASHRAE 62.1-2022. Because 62.1 already requires energy recovery on many large outdoor-air systems, IECC 2024 indirectly tightens ERV expectations, in Climate Zones 4 to 8 an energy recovery ventilator is commonly required where a […]