Heat recovery equipment only delivers its rated savings if it stays clean. Dust, grease, and moisture film raise 압력 손실 and lower effectiveness. A simple maintenance plan protects the investment.
General Inspection Schedule
| 환경 | Inspect | Clean |
|---|---|---|
| Clean office air | Every 6 months | Annually |
| Dusty / industrial | Quarterly | When dP +15-20 % |
| Greasy (kitchen, booth) | Monthly | As needed |
Cleaning by Type
- Plate exchanger: Pull cores, vacuum or wash with mild detergent, rinse, dry, reassemble. Avoid high-pressure jets that bend plates.
- Rotary wheel: Use the manufacturer’s wash cycle or soft brush; never soak the drive motor.
- Heat pipe: Wipe fins; check for bent tubes; verify no freeze damage seasonally.
- 런어라운드 코일: Flush the glycol loop, check concentration, top up as needed.
What to Measure
- Pressure drop across the core vs baseline.
- Supply-air temperature rise vs design.
- Fan current (rises with clogging).
- Visible dust or film on plates/fins.
자주 묻는 질문
Can I pressure-wash plates?
Only with a wide fan nozzle at low pressure; high pressure dents plates and ruins the seal surface.
How do I know it is time to clean?
When measured pressure drop exceeds baseline by 15-20 % or effectiveness drops below spec.
Why a Maintenance Plan Pays
A clogged core can lose 15-30% of its effectiveness and push fan energy up with it. A scheduled inspection costs far less than the lost savings plus emergency downtime. Log pressure drop at commissioning as the baseline, then trend it monthly in harsh environments.
자주 묻는 질문
Can I pressure-wash plates?
Only with a wide fan nozzle at low pressure; high pressure dents plates and ruins the seal surface.
How do I know it is time to clean?
When measured pressure drop exceeds baseline by 15-20% or effectiveness drops below spec.
적합한 열교환기 선정
당사 엔지니어가 풍량, 온도, 압력 손실 예산에 맞춰 코어를 설계하고, 적용에 따라 판형·회전식·히트파이프 회수를 선택합니다. 다음을 읽으세요: 열교환기 가이드 , 또는 사양 관련 문의를 주세요.