Choisir un échangeur de chaleur pour un retrofit HVAC

Retrofitting heat recovery into an existing building is different from designing new. Space, duct layout, and control integration usually drive the choice more than peak efficiency.

Step 1: Audit the Air Streams

  • Confirm there is a dedicated exhaust and a matching supply.
  • Measure airflow (m³/h or CFM) and temperature profiles.
  • Note operating hours — recovery only pays where runtime is high.

Step 2: Pick a Form Factor

Constraint Meilleur ajustement
Exhaust far from supply Boucle à pompe de circulation
No cross-contamination allowed Plate or heat pipe
Humidity control needed roue d'enthalpie
Tight mechanical room Heat pipe (compact)

Step 3: Integrate Controls

  • Add a bypass for mild-weather free cooling.
  • Interlock with existing BMS via dry contacts or BACnet.
  • Use variable-speed fans to follow load.

Step 4: Verify Savings

Before commissioning, baseline energy use. After 3–6 months, compare to confirm payback matches the model.

A retrofit succeeds on planning and verification as much as hardware. Phase the work to avoid shutting down occupied spaces, and confirm the existing duct static pressure before sizing any core so you do not inherit a high-pressure-drop system. Where the exhaust and supply are far apart, a run-around coil keeps the retrofit feasible without re-ducting. Use a measurement and verification plan based on a recognized protocol so the reported savings survive audit: baseline energy, then compare after a full season. Tie the recovery to the existing controls through dry contacts or a network link so it runs only when needed. Our psychrometric guide shows how recovery shifts the air state on the chart.

Questions fréquemment posées

Do I need to replace the AHU?
Usually not. Add-on cores or remote run-around coils can be fitted around existing equipment.

What is the biggest retrofit risk?
Undersized ducts causing high pressure drop; verify static pressure before specifying.

Questions fréquemment posées

Do I need to replace the AHU?

Usually not. Add-on cores or remote run-around coils can be fitted around existing equipment.

What is the biggest retrofit risk?

Undersized ducts causing high pressure drop; verify static pressure before specifying.

Spécifiez le bon échangeur

Nos ingénieurs dimensionnent le noyau selon votre débit, température et budget de perte de charge, et choisissent la récupération par plaque, rotative ou caloduc selon l'application. Lisez le guide de l'échangeur , ou contactez-nous pour une spécification.

Demander un devis

Produits connexes

Air-to-Air Heat Exchanger

Récupération par plaque, rotative ou caloduc pour le CVC et la ventilation.

Plate Heat Exchanger

Noyaux stationnaires à grande surface pour l'air et le liquide.

roue de récupération rotative

Récupération d'énergie à haute efficacité pour grands débits.

Heat Pipe Heat Exchanger

Courants passifs et totalement séparés pour applications propres.

Articles similaires

Commencez à saisir votre recherche ci-dessus et pressez Entrée pour rechercher. ESC pour annuler.

Retour en haut
Calculateurs gratuits de récupération de chaleur et outils de dimensionnement