The hidden reservoir
Showers, wash-down, and process drains leave buildings at 25-40C – warm enough to be a valuable heat source. Wastewater (drain-water) heat recovery captures it before it disappears down the sewer.
Fonctionnement
- Drain-water heat exchangers wrap a coil around or sit inside the greywater stream, pre-warming incoming cold water.
- Heat pumps lift the low-grade wastewater temperature to useful levels for domestic hot water or space heating.
- Unlike air-to-air recovery, this is a water-to-water loop – see air-to-air vs air-to-water.
Best-fit buildings
Swimming pools, gyms, student residences, and laundries with continuous warm drain flow. Pair with the leisure-facility recovery guide for pools.
Design cautions
- Fouling and odor: use accessible, cleanable exchangers and a hair/trap filter.
- Flow matching: recovery tracks drain volume, so size to peak simultaneous use.
Retour sur investissement
In high-hot-water-demand sites, drain-water recovery often pays back in 2-3 years and cuts water-heating energy 30-50%. Validate with a payback calculation.
Temperature lift and the heat pump
Drain water at 25 to 40C is too cool for direct use but ideal as a heat-pump source. A heat pump lifts that low-grade warmth to the 45 to 60C range needed for domestic hot water or space heating, often at a coefficient of performance well above unity. Pairing a drain-water coil with a heat pump captures more of the available energy than passive recovery alone, which matters where hot-water demand is constant.
Flow matching and storage
Recovery tracks drain volume, so the exchanger and any buffer tank should be sized to peak simultaneous use rather than the daily average. A small thermal store smooths the mismatch between when warm water leaves and when it is needed, letting the heat pump run at steadier, more efficient conditions instead of hunting with the drain flow.
Hygiene and access
Greywater carries hair, grease, and odor potential, so the exchanger must be accessible for cleaning and protected by a strainer or hair trap upstream. Choose a design that can be flushed or descaled without removing major piping, and confirm materials resist the mildly corrosive drain environment. Trend the recovered energy to confirm the coil stays clean.
Questions fréquemment posées
What temperature is drain water and can it be used?
Drain water leaves at 25 to 40C. It is too cool for direct use but ideal as a heat-pump source for domestic hot water or space heating.
Which buildings benefit most from drain-water recovery?
Swimming pools, gyms, student residences, and laundries with a continuous warm drain flow benefit most.
What design cautions apply?
Fouling and odor: use accessible, cleanable exchangers and a hair or trap filter upstream. Size to peak simultaneous flow, not the daily average.
What payback is typical?
In high hot-water-demand sites, drain-water recovery often pays back in 2 to 3 years and cuts water-heating energy by 30 to 50 percent. Validate with a payback calculation.
Questions fréquemment posées
What temperature is drain water and can it be used?
Drain water leaves at 25 to 40C. It is too cool for direct use but ideal as a heat-pump source for domestic hot water or space heating.
Which buildings benefit most from drain-water recovery?
Swimming pools, gyms, student residences, and laundries with a continuous warm drain flow benefit most.
What design cautions apply?
Fouling and odor: use accessible, cleanable exchangers and a hair or trap filter upstream. Size to peak simultaneous flow, not the daily average.
What payback is typical?
In high hot-water-demand sites, drain-water recovery often pays back in 2 to 3 years and cuts water-heating energy by 30 to 50 percent. Validate with a payback calculation.
Spécifiez le bon échangeur
Nos ingénieurs dimensionnent le noyau selon votre débit, température et budget de perte de charge, et choisissent la récupération par plaque, rotative ou caloduc selon l'application. Lisez le guide de l'échangeur , ou contactez-nous pour une spécification.
Produits connexes
Récupération par plaque, rotative ou caloduc pour le CVC et la ventilation.
Noyaux stationnaires à grande surface pour l'air et le liquide.
Récupération d'énergie à haute efficacité pour grands débits.
Courants passifs et totalement séparés pour applications propres.