F5-F9 medium efficiency synthetic pocket bag air filter with galvanized steel header

初効率 vs 中効率 vs 高効率フィルター:横並び比較

The Three Tiers at a Glance

Primary (G1-G4) Medium (F5-F9) HEPA/ULPA (H10-H14+)
Removes Coarse dust, hair, fibres Fine dust, pollen, microbes Sub-micron, bacteria, most viruses
Initial ΔP 20-45 Pa 45-95 Pa 100-300 Pa
Life 3-6 months 6-12 months 1-3 years
コスト 低 Medium 高
Typical role Pre-filter Final or pre-HEPA Final in clean/critical spaces

How They Work Together

A sound design stacks them: G4 pre – F7/F9 medium – H13/H14 HEPA. The pre-filter shields the costly stages; the medium lifts IAQ; the HEPA guarantees cleanliness where it counts.

Picking Your Combination

  • Comfort HVAC: G4 + F7.
  • Health-care: G4 + F8 + H13 terminal.
  • Cleanroom: G4 + F9 + H14 (add U15 for ISO 3-4).

Browse our primary, medium と HEPA product guides for model-level specs.

.yc-spec-wrap{margin:36px 0 28px}
.yc-spec-wrap figure{margin:0 0 24px;text-align:center}
.yc-spec-wrap figure img{max-width:100%;height:auto;border:1px solid #e5e7eb;border-radius:8px}
.yc-spec-wrap figcaption{font-size:14px;color:#6b7280;margin-top:8px}
.yc-spec{width:100%;border-collapse:collapse;font-size:15px;margin:8px 0 16px}
.yc-spec th,.yc-spec td{border:1px solid #d1d5db;padding:9px 12px;text-align:left;vertical-align:top}
.yc-spec th{background:#1f3a5f;color:#fff}
.yc-spec tr:nth-child(even) td{background:#f8fafc}
.yc-note{font-size:14px;color:#6b7280;margin-top:4px}
.yc-thumb-row{display:flex;gap:16px;flex-wrap:wrap;margin:0 0 20px}
.yc-thumb-row figure{flex:1 1 240px;margin:0;text-align:center}

Product Line-up & Side-by-Side Specifications

Primary panel air filter G1-G4
Primary — panel / pocket (G1–G4)
Medium efficiency pocket bag air filter F5-F9
Medium — pocket / V-cell (F5–F9)
Deep-pleat HEPA air filter H10-H14
High — HEPA / ULPA (H10–H14)
パラメータ Primary G4 Medium F7 High-efficiency H13
規格 EN 779 / ISO 16890 Coarse EN 779 / ISO 16890 ePM1 EN 1822
効率 90–95% arrestance 80–90% (ePM1 50–65%) ≥ 99.95% @ MPPS
Position in the filtration train 1st stage — protects downstream filters 2nd stage — supply-air quality Terminal — cleanrooms, labs, operating theatres
Typical initial ΔP 45–70 Pa 95–130 Pa 200–250 Pa
Recommended final ΔP 150 Pa 250–300 Pa 450–600 Pa
Typical replacement interval 3–6 months 6–12 months 1–3 years (ΔP based)
Typical applications Outdoor-air and return-air pre-filtration in AHUs Offices, malls, food & pharma HVAC Hospitals, cleanrooms, coating booths, electronics

Rule of thumb: stage primary → medium → high efficiency in series, and let each stage reach its recommended final ΔP before replacement — this is what protects the more expensive stage behind it.

よくある質問

How are the three efficiency tiers distinguished?
They are separated by the particle size they capture and their efficiency: coarse G classes, fine F classes and HEPA H classes.

Which tiers suit a typical office?
A two-stage G4 pre-filter plus an F7 final filter covers general comfort ventilation in most offices.

Why are filters arranged in stages?
Staging lets each tier handle its own size band, protects the finer media and lowers the overall cost of filtration.

Does higher efficiency always mean higher pressure drop?
Usually, but modern media design narrows the gap, so balance energy use against the required level of cleanliness.

よくある質問

How are the three efficiency tiers distinguished?

They are separated by the particle size they capture and their efficiency: coarse G classes, fine F classes and HEPA H classes.

Which tiers suit a typical office?

A two-stage G4 pre-filter plus an F7 final filter covers general comfort ventilation in most offices.

Why are filters arranged in stages?

Staging lets each tier handle its own size band, protects the finer media and lowers the overall cost of filtration.

Does higher efficiency always mean higher pressure drop?

Usually, but modern media design narrows the gap, so balance energy use against the required level of cleanliness.

適切な熱交換器を選定

当社のエンジニアが風量、温度、圧力損失の予算に合わせてコアを設計し、用途に応じて板式・回転式・ヒートパイプ回収を選定します。以下をお読みください: 熱交換器ガイド 、または仕様についてお問い合わせください。

見積りを依頼

関連製品

Air-to-Air Heat Exchanger

HVAC および換気向けの板式・回転式・ヒートパイプ回収。

Plate Heat Exchanger

空気と液体用の大表面積固定コア。

ロータリー熱回収ホイール

大風量向け高効率エネルギー回収。

Heat Pipe Heat Exchanger

清浄用途向けの受動的・完全分離流。

関連投稿

検索語を上に入力し、 Enter キーを押して検索します。キャンセルするには ESC を押してください。

トップに戻る
無料の熱回収計算ツールおよびサイジングツール