F5-F9 medium efficiency synthetic pocket bag air filter with galvanized steel header

Filtres primaires vs moyenne vs haute efficacité : comparaison côte à côte

The Three Tiers at a Glance

Primary (G1-G4) Medium (F5-F9) HEPA/ULPA (H10-H14+)
Removes Coarse dust, hair, fibres Fine dust, pollen, microbes Sub-micron, bacteria, most viruses
Initial ΔP 20-45 Pa 45-95 Pa 100-300 Pa
Life 3-6 months 6-12 months 1-3 years
Coût Faible Medium Élevé
Typical role Pre-filter Final or pre-HEPA Final in clean/critical spaces

How They Work Together

A sound design stacks them: G4 pre – F7/F9 medium – H13/H14 HEPA. The pre-filter shields the costly stages; the medium lifts IAQ; the HEPA guarantees cleanliness where it counts.

Picking Your Combination

  • Comfort HVAC: G4 + F7.
  • Health-care: G4 + F8 + H13 terminal.
  • Cleanroom: G4 + F9 + H14 (add U15 for ISO 3-4).

Browse our primary, medium et HEPA product guides for model-level specs.

.yc-spec-wrap{margin:36px 0 28px}
.yc-spec-wrap figure{margin:0 0 24px;text-align:center}
.yc-spec-wrap figure img{max-width:100%;height:auto;border:1px solid #e5e7eb;border-radius:8px}
.yc-spec-wrap figcaption{font-size:14px;color:#6b7280;margin-top:8px}
.yc-spec{width:100%;border-collapse:collapse;font-size:15px;margin:8px 0 16px}
.yc-spec th,.yc-spec td{border:1px solid #d1d5db;padding:9px 12px;text-align:left;vertical-align:top}
.yc-spec th{background:#1f3a5f;color:#fff}
.yc-spec tr:nth-child(even) td{background:#f8fafc}
.yc-note{font-size:14px;color:#6b7280;margin-top:4px}
.yc-thumb-row{display:flex;gap:16px;flex-wrap:wrap;margin:0 0 20px}
.yc-thumb-row figure{flex:1 1 240px;margin:0;text-align:center}

Product Line-up & Side-by-Side Specifications

Primary panel air filter G1-G4
Primary — panel / pocket (G1–G4)
Medium efficiency pocket bag air filter F5-F9
Medium — pocket / V-cell (F5–F9)
Deep-pleat HEPA air filter H10-H14
High — HEPA / ULPA (H10–H14)
Paramètre Primary G4 Medium F7 High-efficiency H13
Norme EN 779 / ISO 16890 Coarse EN 779 / ISO 16890 ePM1 EN 1822
Efficacité 90–95% arrestance 80–90% (ePM1 50–65%) ≥ 99.95% @ MPPS
Position in the filtration train 1st stage — protects downstream filters 2nd stage — supply-air quality Terminal — cleanrooms, labs, operating theatres
Typical initial ΔP 45–70 Pa 95–130 Pa 200–250 Pa
Recommended final ΔP 150 Pa 250–300 Pa 450–600 Pa
Typical replacement interval 3–6 months 6–12 months 1–3 years (ΔP based)
Typical applications Outdoor-air and return-air pre-filtration in AHUs Offices, malls, food & pharma HVAC Hospitals, cleanrooms, coating booths, electronics

Rule of thumb: stage primary → medium → high efficiency in series, and let each stage reach its recommended final ΔP before replacement — this is what protects the more expensive stage behind it.

Questions fréquemment posées

How are the three efficiency tiers distinguished?
They are separated by the particle size they capture and their efficiency: coarse G classes, fine F classes and HEPA H classes.

Which tiers suit a typical office?
A two-stage G4 pre-filter plus an F7 final filter covers general comfort ventilation in most offices.

Why are filters arranged in stages?
Staging lets each tier handle its own size band, protects the finer media and lowers the overall cost of filtration.

Does higher efficiency always mean higher pressure drop?
Usually, but modern media design narrows the gap, so balance energy use against the required level of cleanliness.

Questions fréquemment posées

How are the three efficiency tiers distinguished?

They are separated by the particle size they capture and their efficiency: coarse G classes, fine F classes and HEPA H classes.

Which tiers suit a typical office?

A two-stage G4 pre-filter plus an F7 final filter covers general comfort ventilation in most offices.

Why are filters arranged in stages?

Staging lets each tier handle its own size band, protects the finer media and lowers the overall cost of filtration.

Does higher efficiency always mean higher pressure drop?

Usually, but modern media design narrows the gap, so balance energy use against the required level of cleanliness.

Spécifiez le bon échangeur

Nos ingénieurs dimensionnent le noyau selon votre débit, température et budget de perte de charge, et choisissent la récupération par plaque, rotative ou caloduc selon l'application. Lisez le guide de l'échangeur , ou contactez-nous pour une spécification.

Demander un devis

Produits connexes

Air-to-Air Heat Exchanger

Récupération par plaque, rotative ou caloduc pour le CVC et la ventilation.

Plate Heat Exchanger

Noyaux stationnaires à grande surface pour l'air et le liquide.

roue de récupération rotative

Récupération d'énergie à haute efficacité pour grands débits.

Heat Pipe Heat Exchanger

Courants passifs et totalement séparés pour applications propres.

Articles similaires

Commencez à saisir votre recherche ci-dessus et pressez Entrée pour rechercher. ESC pour annuler.

Retour en haut
Calculateurs gratuits de récupération de chaleur et outils de dimensionnement