Laundries are heat hogs
Commercial laundries heat vast volumes of water and run dryer exhaust hot and moist all day. Up to 70% of their energy can leave as warm water and humid air. Recovery is the fastest payback in the sector.
Two streams to catch
- Wash water – drain water at 40-60C feeds a water-to-water heat exchanger or heat pump to pre-warm incoming cold water. See wastewater-source recovery.
- Dryer exhaust – warm, humid air gives up heat to make-up air via an enthalpic wheel or plate unit.
Hygiene and fouling
Lint and detergent demand cleanable, accessible cores. Plan a rhythm from our cleaning guide and use a hair/trap filter upstream of any water exchanger.
Retour sur investissement
High hot-water demand means recovery often pays back in 1.5-3 years, cutting water-heating energy 30-50%. Validate with a payback calculation. Leisure sites with on-site laundries (see sports facilities) benefit most.
Water side: the bigger prize
Wash water leaving at 40 to 60C carries the largest share of a laundry energy, so the water-to-water exchanger or heat pump on the drain is usually the fastest payback. A plate or coil unit pre-warms incoming cold water, directly cutting the boiler or electric load needed to reach wash temperature. Where the drain is continuous, a heat pump can lift that warmth to an even higher supply temperature.
Air side: dryer exhaust
Dryer exhaust is hot and humid, ideal for an enthalpic wheel or plate unit that returns both temperature and moisture to the make-up air, reducing the heating needed to replace it. Because dryers run in batches, the recovery should handle part-load gracefully, since a coil or wheel sized only to peak batch flow wastes effectiveness between cycles.
Keeping it clean and measurable
Lint and detergent make the air and water sides fouling-prone, so accessible, cleanable cores and an upstream strainer protect performance and hygiene. Trend the temperature recovery on both sides and the water-heating energy saved, so a falling trend flags a fouled coil before it hits the utility bill. The 30 to 50 percent water-heating saving depends on keeping both streams clean.
Questions fréquemment posées
What are the two laundry heat streams?
Wash water at 40 to 60C handled by a water-to-water exchanger or heat pump, and hot humid dryer exhaust handled by an enthalpic wheel or plate unit.
Which gives the fastest payback?
The wash-water side usually, because it is the largest energy share. A heat pump can lift it to an even higher supply temperature.
What hygiene issues matter?
Lint and detergent demand cleanable, accessible cores and an upstream strainer. Plan a cleaning rhythm.
What payback is typical?
Often 1.5 to 3 years, cutting water-heating energy by 30 to 50 percent. Validate with a payback calculation.
Questions fréquemment posées
What are the two laundry heat streams?
Wash water at 40 to 60C handled by a water-to-water exchanger or heat pump, and hot humid dryer exhaust handled by an enthalpic wheel or plate unit.
Which gives the fastest payback?
The wash-water side usually, because it is the largest energy share. A heat pump can lift it to an even higher supply temperature.
What hygiene issues matter?
Lint and detergent demand cleanable, accessible cores and an upstream strainer. Plan a cleaning rhythm.
What payback is typical?
Often 1.5 to 3 years, cutting water-heating energy by 30 to 50 percent. Validate with a payback calculation.
Spécifiez le bon échangeur
Nos ingénieurs dimensionnent le noyau selon votre débit, température et budget de perte de charge, et choisissent la récupération par plaque, rotative ou caloduc selon l'application. Lisez le guide de l'échangeur , ou contactez-nous pour une spécification.
Produits connexes
Récupération par plaque, rotative ou caloduc pour le CVC et la ventilation.
Noyaux stationnaires à grande surface pour l'air et le liquide.
Récupération d'énergie à haute efficacité pour grands débits.
Courants passifs et totalement séparés pour applications propres.