Commercial Building Heat Recovery: Offices, Hotels, Mixed-Use

The everyday opportunity

Offices, hotels, and mixed-use buildings run ventilation around the clock with high fresh-air rates. Recovering that exhaust energy is the single biggest HVAC saving for most commercial stock.

Technology mix

Climate matters

Use climate-based selection: enthalpic cores in humid zones, sensible plate in dry ones. Keep wheel upkeep in mind if you choose rotary.

Retour sur investissement

Most commercial retrofits pay back in 3-5 years. Size with our payback method and verify with efficiency metrics.

Where the savings come from

  • Make-up air pre-conditioning – the largest load in continuously ventilated buildings.
  • Reduced boiler and chiller runtime, especially during shoulder seasons.
  • Smaller HVAC plant if recovery is specified early in design.

Specification tips

Favor sensible plate cores in dry climates and enthalpy wheels where humidity control dominates. Size the core from measured airflow, not nameplate, and keep a maintenance window for filter and wheel service.

Questions fréquemment posées

What payback can commercial buildings expect?
Most retrofits pay back in 3-5 years through lower heating, cooling and fan energy.

Plate or rotary for an office AHU?
Balanced offices usually suit plate or rotary; choose rotary when humidity recovery matters, plate when contamination control is tighter.

Do hotels need special handling?
Guest rooms, laundry and pools add latent loads, so enthalpy recovery often pays; pair it with the building central plant.

Questions fréquemment posées

What payback can commercial buildings expect?

Most retrofits pay back in 3-5 years through lower heating, cooling and fan energy.

Plate or rotary for an office AHU?

Balanced offices usually suit plate or rotary; choose rotary when humidity recovery matters, plate when contamination control is tighter.

Do hotels need special handling?

Guest rooms, laundry and pools add latent loads, so enthalpy recovery often pays; pair it with the building central plant.

Spécifiez le bon échangeur

Nos ingénieurs dimensionnent le noyau selon votre débit, température et budget de perte de charge, et choisissent la récupération par plaque, rotative ou caloduc selon l'application. Lisez le guide de l'échangeur , ou contactez-nous pour une spécification.

Demander un devis

Produits connexes

Air-to-Air Heat Exchanger

Récupération par plaque, rotative ou caloduc pour le CVC et la ventilation.

Plate Heat Exchanger

Noyaux stationnaires à grande surface pour l'air et le liquide.

roue de récupération rotative

Récupération d'énergie à haute efficacité pour grands débits.

Heat Pipe Heat Exchanger

Courants passifs et totalement séparés pour applications propres.

Articles similaires

Commencez à saisir votre recherche ci-dessus et pressez Entrée pour rechercher. ESC pour annuler.

Retour en haut
Calculateurs gratuits de récupération de chaleur et outils de dimensionnement