Récupération d'enthalpie vs sensible

Heat recovery is often described as “sensible” or “enthalpy.” The difference decides comfort, energy savings, and which technology to specify.

Sensible Recovery

Transfers temperature only. Plate exchangers, heat pipes, and run-around coils are sensible devices. They pre-heat or pre-cool the supply air without adding or removing moisture.

Enthalpy Recovery

Transfers both temperature and moisture. Enthalpy rotary wheels and some membranes move water vapor, which can cut cooling and dehumidification loads in humid climates.

Which Should You Choose?

Condition Meilleur choix
Cold, dry climate Sensible (avoid adding moisture indoors)
Hot, humid climate Enthalpy (reduce cooling + dehumidification)
Drying / exhaust with moisture Sensible (don’t return humidity)
Swimming pool / ice rink roue d'enthalpie

Energy Impact

Enthalpy recovery can reduce total HVAC energy by an additional 10–30 % versus sensible-only in humid regions, because it offsets both latent and sensible loads.

Questions fréquemment posées

Does enthalpy recovery spread bacteria?
Modern enthalpy wheels use antimicrobial coatings and purge sectors; risk is low when maintained per manufacturer guidance.

Can a plate exchanger do enthalpy?
Only special enthalpy plates or membranes; standard aluminum plates are sensible-only.

Practical Notes

  • In cold, dry winters, sensible recovery avoids over-humidifying indoor air.
  • In cooling-dominated, humid climates, enthalpy recovery is usually worth the extra complexity.
  • For drying or process exhaust that must not return moisture, stay sensible.

Sizing note

When comparing sensible and enthalpy recovery, size from the actual ventilation airflow and the design temperature difference, not nameplate. A 10 C supply-air temperature rise recovered at 80% effectiveness removes most of the heating load before the coil – the choice between sensible and enthalpy then decides how much latent load the cooling coil must also handle.

Questions fréquemment posées

Does enthalpy recovery spread bacteria?

Modern enthalpy wheels use antimicrobial coatings and purge sectors; risk is low when maintained per manufacturer guidance.

Can a plate exchanger do enthalpy?

Only special enthalpy plates or membranes; standard aluminum plates are sensible-only.

Spécifiez le bon échangeur

Nos ingénieurs dimensionnent le noyau selon votre débit, température et budget de perte de charge, et choisissent la récupération par plaque, rotative ou caloduc selon l'application. Lisez le guide de l'échangeur , ou contactez-nous pour une spécification.

Demander un devis

Produits connexes

Air-to-Air Heat Exchanger

Récupération par plaque, rotative ou caloduc pour le CVC et la ventilation.

Plate Heat Exchanger

Noyaux stationnaires à grande surface pour l'air et le liquide.

roue de récupération rotative

Récupération d'énergie à haute efficacité pour grands débits.

Heat Pipe Heat Exchanger

Courants passifs et totalement séparés pour applications propres.

Articles similaires

Commencez à saisir votre recherche ci-dessus et pressez Entrée pour rechercher. ESC pour annuler.

Retour en haut
Calculateurs gratuits de récupération de chaleur et outils de dimensionnement