An air handling unit (AHU) conditions outdoor air before it enters a building. Without recovery, that outdoor air must be heated or cooled from scratch every hour. Adding a heat recovery core to the AHU is the single highest-impact energy measure for ventilation systems.
Where the Exchanger Sits in an AHU
The recovery core is placed in the exhaust-to-supply air path, usually after the filters and before the supply fan. In modular AHUs, it drops into a dedicated section sized for the core dimensions.
Matching Exchanger Type to AHU Duty
| AHU duty | Recommended core |
|---|---|
| General office fresh air | Counter-flow plate or enthalpy wheel |
| Laboratory / hospital (clean) | Plate (no carryover) |
| High humidity climate | 回転式エンタルピーホイール |
| Retrofit, limited space | Heat pipe or run-around coil |
Integration Tips
- Keep face velocity in the 2–3 m/s range for balanced efficiency and pressure drop.
- Add bypass dampers for free cooling in mild weather.
- Use EC fans to capture part-load savings.
- Specify easy-access doors for core cleaning.
当社の modular AHU solutions for recovery-ready configurations.
Factory assembly and casing quality matter as much as the core itself. Specify a casing leakage class per EN 1886 so recovered air is not lost to the mechanical room, and confirm the core section has tool-free access doors for service. Place the filter stages ahead of the recovery core to protect it, and keep the supply fan after the core to avoid pressurizing the exhaust side. For clean applications, verify that face velocity and core bypass meet the required air-change rates. Commission the unit with the building management system so the bypass opens on cool days and the recovery core carries the heating or cooling load the rest of the year. Explore modular AHU solutions with recovery-ready sections in standard sizes.
よくある質問
Can I retrofit an existing AHU?
Yes, if there is physical space and a matching exhaust duct. Heat pipes and run-around coils are the most retrofit-friendly.
Does recovery hurt IAQ?
No. Plate and heat-pipe cores keep streams separate; only enthalpy wheels transfer a little moisture, which is managed by purge sectors.
よくある質問
Can I retrofit an existing AHU?
Yes, if there is physical space and a matching exhaust duct. Heat pipes and run-around coils are the most retrofit-friendly.
Does recovery hurt IAQ?
No. Plate and heat-pipe cores keep streams separate; only enthalpy wheels transfer a little moisture, which is managed by purge sectors.
適切な熱交換器を選定
当社のエンジニアが風量、温度、圧力損失の予算に合わせてコアを設計し、用途に応じて板式・回転式・ヒートパイプ回収を選定します。以下をお読みください: 熱交換器ガイド 、または仕様についてお問い合わせください。
関連製品
HVAC および換気向けの板式・回転式・ヒートパイプ回収。
空気と液体用の大表面積固定コア。
大風量向け高効率エネルギー回収。
清浄用途向けの受動的・完全分離流。